V1R2 changes
F5 BIG-IP TMOS Firewall STIG V1R2 (2026-09-30) replaced V1R1 (2024-09-26): 1 check added, 1 removed, 3 updated. It has 14 checks, against 14 in V1R1.
V1R2 checklistV1R1 checklist Compare V1R1 and V1R2 in STIG Compare
- 1 added
- 1 removed
- 3 updated
Updated fields: Discussion 3
Added in V1R2 (1)
- V-289261CAT IIThe F5 BIG-IP appliance must generate traffic log entries containing information to establish the details of the event, including success or failure of the application of the firewall rule.
Removed since V1R1 (1)
- V-266256CAT IIThe F5 BIG-IP appliance must generate traffic log entries containing information to establish the details of the event, including success or failure of the application of the firewall rule.
Updated in V1R2 (3)
V-266254CAT IIThe F5 BIG-IP appliance that filters traffic from the VPN access points must be configured with organization-defined filtering rules that apply to the monitoring of remote access traffic.Discussion
Discussion
Remote access devices (such as those providing remote access to network devices and information systems) that lack automated capabilities increase risk and make remote user access management difficult at best.
Remote access is access to DODDoW nonpublic information systems by an authorized user (or an information system) communicating through an external, nonorganization-controlled network.
Automated monitoring of remote access sessions allows organizations to detect cyber attacks and also ensure ongoing compliance with remote access policies by auditing connection activities of remote access capabilities from a variety of information system components (e.g., servers, workstations, notebook computers, smart phones, and tablets).
V-266257CAT IIIIn the event that communication with the central audit server is lost, the F5 BIG-IP appliance must continue to queue traffic log records locally.Discussion
Discussion
It is critical that when the network element is at risk of failing to process traffic logs as required, it takes action to mitigate the failure. Audit processing failures include software/hardware errors, failures in the audit capturing mechanisms, and audit storage capacity being reached or exceeded. Responses to audit failure depend on the nature of the failure mode.
In accordance with DODDoW policy, the traffic log must be sent to a central audit server. When logging functions are lost, system processing cannot be shut down because firewall availability is an overriding concern given the role of the firewall in the enterprise. The system must either be configured to log events to an alternative server or queue log records locally. Upon restoration of the connection to the central audit server, action must be taken to synchronize the local log data with the central audit server.
If the central audit server uses UDP communications instead of a connection oriented protocol such as TCP, a method for detecting a lost connection must be implemented.
V-266262CAT IIIThe F5 BIG-IP appliance must generate an alert that can be forwarded to, at a minimum, the information system security officer (ISSO) and information system security manager (ISSM) when denial-of-service (DoS) incidents are detected.Discussion
Discussion
Without an alert, security personnel may be unaware of major detection incidents that require immediate action, and this delay may result in the loss or compromise of information.
The firewall generates an alert that notifies designated personnel of the Indicators of Compromise (IOCs), which require real-time alerts. These messages must include a severity level indicator or code as an indicator of the criticality of the incident. These indicators reflect the occurrence of a compromise or a potential compromise.
Since these incidents require immediate action, these messages are assigned a critical or level 1 priority/severity, depending on the system's priority schema.
CJCSM 6510.01B, "Cyber Incident Handling Program", lists nine Cyber Incident and Reportable Event Categories. DODDoW has determined that categories identified by CJCSM 6510.01B Major Indicators (category 1, 2, 4, or 7 detection events) will require an alert when an event is detected.
Alerts may be transmitted, for example, telephonically, by electronic mail messages, or by text messaging. The firewall must either send the alert to a management console that is actively monitored by authorized personnel or use a messaging capability to send the alert directly to designated personnel.
How these changes are found
Checks are matched across the two releases by V-number. A check counts as updated when DISA gave it a new rule revision (the r number in its SV-…_rule id) and its title, severity, check text, fix text, discussion, CCIs or other fields changed — the same comparison STIG Compare makes. Added checks are new V-numbers; removed checks are V-numbers V1R2 no longer has.