V-268244CAT IIThe HYCU virtual appliance must generate log records for a locally developed list of auditable events.Check text
Check text
Log in to the HYCU VM console.
Review the "/etc/audit/auditd.conf" file and verify the settings are in accordance with a locally developed list of auditable events.
If it is not configured in accordance with organizational policies, this is a finding.
Check for the value of the "max_log_file_action" option in "/etc/audit/auditd.conf" with the following command:
sudo grep max_log_file_action /etc/audit/auditd.conf
If the "max_log_file_action" value is not set to "ROTATIONROTATE", this is a finding.
How these changes are found
Checks are matched across the two releases by V-number. A check counts as updated when DISA gave it a new rule revision (the r number in its SV-…_rule id) and its title, severity, check text, fix text, discussion, CCIs or other fields changed — the same comparison STIG Compare makes. Added checks are new V-numbers; removed checks are V-numbers V1R3 no longer has.