The network device must use its loopback or OOB management interface address as the source address when originating syslog traffic.
Description
Discussion Text
Using a loopback address as the source address offers a multitude of uses for security, access, management, and scalability of routers. It is easier to construct appropriate ingress filters for router management plane traffic destined to the network management subnet since the source addresses will be from the range used for loopback interfaces instead of a larger range of addresses used for physical interfaces. Log information recorded by authentication and syslog servers will record the router's loopback address instead of the numerous physical interface addresses. Syslog messages sent to management servers should use the loopback address as the source address.