V1R2 changes
Nutanix AOS 5.20.x Application STIG V1R2 (2024-07-24) replaced V1R1 (2022-09-08): 1 check updated. It has 23 checks, against 23 in V1R1.
V1R2 checklistV1R1 checklist Compare V1R1 and V1R2 in STIG Compare
- 0 added
- 0 removed
- 1 updated
Updated fields: Check text 1Fix text 1Severity 1
Updated in V1R2 (1)
V-254119CAT INutanix AOS must be running an operating system release that is currently supported by the vendor.Severity, Check text, Fix text
Severity
mediumhigh
Check text
1.Product Log in to the Prism Element web interface.
2. Click on the person's name that just logged in.
3. In the drop down menu, click "About Nutanix".
4. Compare the Nutanix AOS version againstis theend supportedof versionslife inand theno Nutanixlonger support portalsupported.
https://www.nutanix.com/support-services/product-support
If the AOSsystem version is notrunning supportedAOS asversion indicated in the Nutanix support portal5.20.x, this is a finding.
Fix text
Use Nutanix LCM and upgrade to a supported version.
How these changes are found
Checks are matched across the two releases by V-number. A check counts as updated when DISA gave it a new rule revision (the r number in its SV-…_rule id) and its title, severity, check text, fix text, discussion, CCIs or other fields changed — the same comparison STIG Compare makes. Added checks are new V-numbers; removed checks are V-numbers V1R2 no longer has.
Comparing other releases, or this one against an older release? Pick any two in STIG Compare.