Search filters this STIG's checks locally. Separate terms must all match (use quotes for an exact phrase). A search you ran on the Search page carries over here.
Assessment Title
Rule Text
AccessLogValve must be configured for Catalina engine.
Description
Discussion Text
The <Engine> container represents the entire request processing machinery associated with a particular Catalina Service. It receives and processes all requests from one or more connectors, and returns the completed response to the connector for transmission back to the client. The AccessLogValve will log activity for the Catalina service.
Exactly one engine element MUST be nested inside a service element, following all of the corresponding connector elements associated with the service.
Satisfies: SRG-APP-000495-AS-000220, SRG-APP-000381-AS-000089, SRG-APP-000499-AS-000224, SRG-APP-000504-AS-000229
Exactly one engine element MUST be nested inside a service element, following all of the corresponding connector elements associated with the service.
Satisfies: SRG-APP-000495-AS-000220, SRG-APP-000381-AS-000089, SRG-APP-000499-AS-000224, SRG-APP-000504-AS-000229