Search filters this STIG's checks locally. Separate terms must all match (use quotes for an exact phrase). A search you ran on the Search page carries over here.
Assessment Title
Rule Text
An ISDN-based VTC system supporting secure (classified) and non-secure (unclassified) conferences while implementing dialing capability from the CODEC must utilize an approved EIA-366-A dial isolator that disconnects the dialing channel between the CODEC and IMUX when the IMUX signals it is connected to another IMUX (i.e., the session is connected).
Description
Discussion Text
When dialing is performed from the CODEC, an EIA-366 connection is made between the CODEC and the IMUX to carry the dialing instructions to the IMUX which actually performs the dialing function.
This is not an issue if there is no EIA-366-A connection between the CODEC and the IMUX and all dialing is performed from the IMUX.
This is not an issue if there is no EIA-366-A connection between the CODEC and the IMUX and all dialing is performed from the IMUX.