What changed in z/OS Compuware Abend-AID for ACF2 STIG V7R2V7R2 changes

z/OS Compuware Abend-AID for ACF2 STIG V7R2 (2025-10-01) replaced V7R1 (2025-01-30): 5 checks updated. It has 6 checks, against 6 in V7R1.

  • 0 added
  • 0 removed
  • 5 updated

Updated fields: Check text 5Fix text 5Discussion 4Title 3

Updated in V7R2 (5)

V-224290CAT IICompuware Abend-AID installation datasets will be properly protected.Title, Check text, Fix text, Discussion

Title

Compuware Abend-AID installation data sets will be properly protected.

Check text

Refer to the following report produced by the Datadataset Set and Resource Data Collection: - SENSITVE.RPT(AIDRPT). Automated Analysis Refer to the following report produced by the Datadataset Set and Resource Data Collection: - PDI(ZAID0000). Verify that the accesses to the Compuware Abend-AID installation datadatasets sets are properly restricted. If the following guidance is true, this is not a finding. ___ The ACF2 datadataset set rules for the datadatasets setsrestrict restricts READ access to all authorized users. ___ The ACF2 datadataset set rules for the datadatasets setsrestrict restricts WRITE and/or greater access to systems programming personnel. ___ The ACF2 datadataset set rules for the datadatasets sets specify that all (i.e., failures and successes) WRITE and/or greater access is logged.

Fix text

The ISSO will ensure that WRITE and/or greater access to Compuware Abend-AID installation datadatasets sets is limited to systems programmers only, and all WRITE and/or greater access is logged. READ access can be given to all authorized users. The installing systems programmer will identify and document the product datadatasets, sets and categorize them according to who will have WRITE and/or greater access, and if required, ensure that all WRITE and/or greater access is logged. The installing systems programmer will identify if any additional groups have WRITE and/or greater access for specific data setsdatasets, and once documented will work with the ISSO to seeensure that they are properly restricted to the ACP (Access Control Program) active on the system. DataDatasets sets to be protected will be: SYS2.ABENDAID. SYS2A.ABENDAID. SYS3A.ABENDAID. The following commands are provided as a sample for implementing datadataset set controls: $KEY(S2A) $PREFIX(SYS2) ABENDAID.V-.- UID(syspaudt) R(A) W(L) A(L) E(A) ABENDAID.V-.- UID(authorized users/*) R(A) E(A) SET RULE COMPILE 'ACF2.MVA.DSNRULES(S2A)' STORE $KEY(SYS2A0A) $MODE(ABORT) $PREFIX(SYS2A) ABENDAID.V-.- UID(syspaudt) R(A) W(L) A(L) E(A) ABENDAID.V-.- UID(authorized users/*) R(A) E(A) SET RULE COMPILE 'ACF2.MVA.DSNRULES(SYS2A0A)' STORE $KEY(SYS3A0A) $PREFIX(SYS3A) ABENDAID.V-.- UID(syspaudt) R(A) W(L) A(L) E(A) ABENDAID.V-.- UID(authorized users/*) R(A) E(A) SET RULE COMPILE 'ACF2.MVA.DSNRULES(SYS3A0A)' STORE

Discussion

Compuware Abend-AID installation datadatasets sets have the ability to use privileged functions and/or have access to sensitive data. Failure to properly restrict access to these datadatasets sets could result in violating the integrity of the base product, which could result in compromising the operating system or sensitive data.

V-224291CAT IICompuware Abend-AID STC datasets must be properly protected.Title, Check text, Fix text, Discussion

Title

Compuware Abend-AID STC data sets must be properly protected.

Check text

Refer to the following report produced by the Datadataset Set and Resource Data Collection: - SENSITVE.RPT(AIDSTC). Automated Analysis Refer to the following report produced by the Datadataset Set and Resource Data Collection: - PDI(ZAID0001). Verify that the accesses to the Compuware Abend-AID STC datadatasets sets are properly restricted. If the following guidance is true, this is not a finding. ___ The ACF2 datadataset set rules for the datadatasets setsrestrict restricts READ access to auditors. ___ The ACF2 datadataset set rules for the datadatasets setsrestrict restricts WRITE and/or greater access to systems programming personnel. ___ The ACF2 datadataset set rules for the datadatasets setsrestrict restricts WRITE and/or greater access to the Compuware Abend-AID's STC(s) and/or batch user(s).

Fix text

The ISSO will ensure that WRITE and/or greater access to Compuware Abend-AID STC datadatasets sets is limited to systems programmers and/or Compuware Abend-AID's STC(s) and/or batch user(s) only. READ access can be given to auditors. The installing systems programmer will identify and document the product datadatasets, sets and categorize them according to who will have WRITE and/or greater access, and if required, ensure that all WRITE and/or greater access is logged. The installing systems programmer will identify if any additional groups have WRITE and/or greater access for specific data setsdatasets, and once documented will work with the ISSO to ensure they are properly restricted to the ACP (Access Control Program) active on the system. DataDatasets sets to be protected will be: SYS3.ABENDAID. The following commands are provided as a sample for implementing datadataset set controls: $KEY(SYS3) ABENDAID.- UID(&ltsyspaudt>) R(A) W(A) A(A) E(A) ABENDAID.- UID(&lttstcaudt>) R(A) W(A) A(A) E(A) ABENDAID.- UID(ABENDAID STCs) R(A) W(A) A(A) E(A) ABENDAID.- UID(&ltaudtaudt>) R(A) E(A)

Discussion

Compuware Abend-AID STC datadatasets sets have the ability to use privileged functions and/or have access to sensitive data. Failure to properly restrict access to these datadatasets sets could result in violating the integrity of the base product which could result in compromising the operating system or sensitive data.

V-224292CAT IICompuware Abend-AID user datasets must be properly protected.Title, Check text, Fix text, Discussion

Title

Compuware Abend-AID user data sets must be properly protected.

Check text

Refer to the following report produced by the Datadataset Set and Resource Data Collection: - SENSITVE.RPT(AIDUSER). Automated Analysis Refer to the following report produced by the Datadataset Set and Resource Data Collection: - PDI(ZAID0002). Verify that the accesses to the following Compuware Abend-AID user datadatasets sets are properly restricted: Region. dump datasets Report databases Source listing files/source listing shared directories If the following guidance is true, this is not a finding. ___Region dump datasets Report databases Source listing files/source listing shared directories The ACF2 datadataset set rules for the listed datadatasets setsrestrict restricts READ access to auditors. ___ The ACF2 datadataset set rules for the listed datadatasets setsrestrict restricts WRITE and/or greater access to systems programming personnel. ___ The ACF2 datadataset set rules for the listed datadatasets setsrestrict restricts WRITE and/or greater access to the Compuware Abend-AID's STC(s) and/or batch user(s). ___ The ACF2 datadataset set rules for the listed datadatasets setsrestrict restricts WRITE access to Applicationapplication Developmentdevelopment Programmersprogrammers and Application Production Support Team members.

Fix text

Ensure that WRITE and/or greater access to Compuware Abend-AID user datadatasets sets is limited to systems programmers and Compuware Abend-AID STC(s) and/or batch user(s) only. Ensure that WRITE access to Compuware Abend-AID user datadatasets sets is limited to Applicationapplication Developmentdevelopment Programmersprogrammers and Application Production Support Team members. ReadREAD access can be given to auditors. (Note: The datadatasets sets and/or datadataset set prefixes identified below are examples of a possible installation. The actual datadatasets sets and/or prefixes are determined when the product is actually installed on a system through the product's installation guide and can be site specific.) DataDatasets sets to be protected will be: Region dump datasets Report databases Source listing files/source listing shared directories The following commands are provided as a sample for implementing datadataset set controls: $KEY(S3A) $PREFIX(SYS3) ABENDAID.SHARED-.- UID(appdaudt) R(A) W(A) ABENDAID.SHARED-.- UID(appsaudt) R(A) W(A) ABENDAID.SHARED-.- UID(AbendAID STCs) R(A) W(A) A(A) E(A) ABENDAID.SHARED-.- UID(syspaudt) R(A) W(A) A(A) E(A) ABENDAID.SHARED-.- UID(tstcaudt) R(A) W(A) A(A) E(A) ABENDAID.SHARED-.- UID(audtaudt) R(A) ABENDAID.REPORTDB-.- UID(appdaudt) R(A) W(A) ABENDAID.REPORTDB-.- UID(appsaudt) R(A) W(A) ABENDAID.REPORTDB-.- UID(AbendAID STCs) R(A) W(A) A(A) E(A) ABENDAID.REPORTED-.- UID(syspaudt) R(A) W(A) A(A) E(A) ABENDAID.REPORTED-.- UID(tstcaudt) R(A) W(A) A(A) E(A) ABENDAID.REPORTDB-.- UID(audtaudt) R(A) SET RULE COMPILE 'ACF2.MVA.DSNRULES(S3A)' STORE

Discussion

Compuware Abend-AID user datadatasets sets have the ability to use privileged functions and/or have access to sensitive data. Failure to properly restrict access to these datadatasets sets could result in violating the integrity of the base product, which could result in compromising the operating system or sensitive data.

V-224293CAT IICompuware Abend-AID resources must be properly defined and protected.Check text, Fix text

Check text

Refer to the following report produced by the ACF2 Data Collection and Datadataset Set and Resource Data Collection: - SENSITVE.RPT(ZAID0020). - ACF2CMDS.RPT(RESOURCE) - Alternate report. Automated Analysis Refer to the following report produced by the Datadataset Set and Resource Data Collection: - PDI(ZAID0020). NOTENote: The Abend-AID resource class is identified in the Enterprise Common Components (ECC) STC procedure, CWPARM DD statement, member name AAVW00, using the parameter setting EXTERNAL_SECURITY_RESOURCE_CLASS. Verify that the accesses to resources and/or generic equivalent are properly restricted according to the requirements specified in the Compuware Abend-AID Resources table in the z/OS STIG Addendum. If the following guidance is true, this is not a finding. ___ The ACF2 resources are defined with a default access of PREVENT. ___ The ACF2 resource access authorizations restrict access to the appropriate personnel.

Fix text

Ensure that the following are properly specified in the ACP. (Note: The resources and/or resource prefixes identified below are examples of a possible installation. The actual resources and/or prefixes are determined when the product is actually installed on a system through the product's installation guide and can be site specific.) Use the Compuware Abend-AID Resources and Compuware Abend-AID Resources Descriptions tables in the zOS STIG Addendum. These tables list the resources, access requirements, and logging requirement for Compuware Abend-AID. Ensure the guidelines for the resources and/or generic equivalent specified in the z/OS STIG Addendum are followed. Note: The Compuware Abend-AID resource class is identified in the Viewer Server's STC configuration procedure, CWPARM DD statement, member name AAVW00, using the parameter setting EXTERNAL_SECURITY_RESOURCE_CLASS. In addition, there is a parameter that identifies the prefix for all resources, which is EXTERNAL_SECURITY_PREFIX. The ACF2 resources as designated in the above table are defined with a default access of PREVENT. The ACF2 resource access authorizations restrict access to the appropriate personnel as designated in the above table. The following commands are provided as a sample for implementing resource controls: $KEY(prefix) TYPE(resource-type) SERVER.LOGON.FD.- UID(appdaudt) ALLOW SERVER.LOGON.FD.- UID(appsaudt) ALLOW SERVER.LOGON.FD.- UID(operaudt) ALLOW SERVER.LOGON.FD.- UID(syspaudt) ALLOW - UID(*) PREVENT

V-224294CAT IICompuware Abend-AID Started Task name will be properly identified and/or defined to the system ACP.Check text, Fix text, Discussion

Check text

Refer to the following report produced by the ACF2 Data Collection: - ACF2CMDS.RPT(ATTSTC). Verify that the logonid(s) for the Compuware Abend-AID started task(s) is (are) properly defined. If the following attributes are defined, this is not a finding. STC

Fix text

The IAOISSO working with the systems programmer will ensure the Compuware Abend-AID Started Task(s) is properly identified and/or defined to the System ACP. If the product requires a Started Task, verify that it is properly defined to the System ACP with the proper attributes. Most installation manuals will indicate how the Started Task is identified and any additional attributes that must be specified. The following commands are provided as a sample for defining Started Task(s): SET LID insert AAVIEWER stc name('STC, Compuware Abend-AID Viewer') insert BDCAS stc name('STC, Compuware Abend-AID') insert TDCAS stc name('STC, Compuware Abend-AID for CICS')

Discussion

Compuware Abend-AID requires a started task that will be restricted to certain resources, datasets, and other system functions. ByDefining defining the started task as a userid to the system ACP, It allows the ACP to control the access and authorized users that require these capabilities. Failure to properly control these capabilities, could compromise of the operating system environment, ACP, and customer data.

How these changes are found

Checks are matched across the two releases by V-number. A check counts as updated when DISA gave it a new rule revision (the r number in its SV-…_rule id) and its title, severity, check text, fix text, discussion, CCIs or other fields changed — the same comparison STIG Compare makes. Added checks are new V-numbers; removed checks are V-numbers V7R2 no longer has.

Comparing other releases, or this one against an older release? Pick any two in STIG Compare.