What changed in z/OS ROSCOE for RACF STIG V7R2V7R2 changes

z/OS ROSCOE for RACF STIG V7R2 (2025-10-01) replaced V7R1 (2025-04-02): 7 checks updated. It has 7 checks, against 7 in V7R1.

  • 0 added
  • 0 removed
  • 7 updated

Updated fields: Check text 7Fix text 5Discussion 3Title 1

Updated in V7R2 (7)

V-224528CAT IIROSCOE Install data sets are not properly protected.Check text, Fix text

Check text

Refer to the following report produced by the Data Set and Resource Data Collection: - SENSITVE.RPT(ROSRPT). Automated Analysis Refer to the following report produced by the Data Set and Resource Data Collection: - PDI(ZROS0000). Verify that access to the ROSCOE Install data set are properly restricted. If the following guidance is true, this is not a finding. The RACF data set rules for the data sets does not restrict UPDATEWRITE and/or ALTERgreater access to systems programming personnel. The RACF data set rules for the data sets does not specify that all (i.e., failures and successes) UPDATEWRITE and/or ALTERgreater access will be logged. If all of the above are untrue, this is not a finding. If any of the above is true, this is a finding.

Fix text

The ISSO will ensure that updateWRITE and/or altergreater access to program product data sets is limited to system programmers, security personnel and auditors only, and all updateWRITE and/or allocategreater access is logged. The installing systems programmer will identify and document the product data sets and categorize them according to who will have updateWRITE and/or altergreater access and if required that all updateWRITE and/or altergreater access is logged. The installing systems programmer will identify if any additional groups have updateUPDATE access for specific data sets, and once documented, will work with the ISSO to ensure they are properly restricted to the Access Control Program (ACP) active on the system. Data set prefix to be protected will be: SYS2.ROSCOE. SYS2A.ROSCOE. SYS3.ROSCOE. SYS3A.ROSCOE. The following commands are provided as a sample for implementing datasetdata set controls: ad 'sys2.roscoe.**' uacc(none) owner(sys2) - audit(success(update) failures(read)) - data('Vendor DS Profile: ROSCOE') pe 'sys2.roscoe.**' id(syspaudt) acc(a) pe 'sys2.roscoe.**' id(*) acc(r) ad 'sys2a.roscoe.**' uacc(none) owner(sys2a) - audit(success(update) failures(read)) - data('Roscoe Vendor Datasets') pe 'sys2a.roscoe.**' id(&ltsyspaudt>) acc(a) pe 'sys2a.roscoe.**' id(*) acc(r) ad 'sys3.roscoe.**' uacc(none) owner(sys3) - audit(success(update) failures(read)) - data('Roscoe Vendor Datasets') pe 'sys3.roscoe.**' id(&ltsyspaudt>) acc(a) pe 'sys3.roscoe.**' id(*) acc(r) ad 'sys3a.roscoe.**' uacc(none) owner(sys3a) - audit(success(update) failures(read)) - data('Roscoe Vendor Datasets') pe 'sys3a.roscoe.**' id(&ltsyspaudt>) acc(a) pe 'sys3a.roscoe.**' id(*) acc(r) setr generic(dataset) refresh

V-224529CAT IIROSCOE STC data sets are not properly protected.Check text, Fix text

Check text

a) Refer to the following report produced by the Data Set and Resource Data Collection: - SENSITVE.RPT(ROSSTC). Automated Analysis Refer to the following report produced by the Data Set and Resource Data Collection: - PDI(ZROS0001). b) Verify that access to the ROSCOE STC data sets areis properly restricted. The data sets in this group are the data sets identified in the ROSACTxx (if used), ROSLIBxx, and SYSAWSx DD statements of the STC or batch JCL. If the following guidance is true, this is not a finding. ___ The RACF data set rules for the data sets does not restrict UPDATEWRITE and/or ALTERgreater access to systems programming personnel. ___ The RACF data set rules for the data sets does not restrict UPDATEWRITE and/or ALTERgreater access to the product STC(s) and/or batch job(s). c) If all of the above are untrue, there is NO FINDING. d) If any of the above is true, this is a FINDING.

Fix text

The IAOISSO will ensure that updateWRITE and/or altergreater access to the ROSCOE started task or batch job data sets is limited to system programmers and the started task only and all updateWRITE and/or altergreater access is logged. The IAOISSO will ensure that all other accesses to the ROSCOE started task or batch job data sets are properly restricted and all required accesses are properly logged. Data sets to be protected will be: SYS3.ROSCOE.sys*.** SYS3.ROSCOE.ros*.** The following commands are provided as a sample for implementing datasetdata set controls: ad 'sys3.roscoe.ros*.**' uacc(none) owner(sys3) - audit(success(update) failures(read)) - data('Site Customized Profile: ROSCOE') pe 'sys3.roscoe.ros*.**' id(syspaudt) acc(a) pe 'sys3.roscoe.ros*.**' id(roscoe) acc(a) ad 'sys3.roscoe.sys*.**' uacc(none) owner(sys3) - audit(success(update) failures(read)) - data('Site Customized profile: ROSCOE') pe 'sys3.roscoe.sys*.**' id(syspaudt) acc(a) pe 'sys3.roscoe.sys*.**' id(roscoe) acc(a) setr generic(dataset) refresh

V-224530CAT IIROSCOE resources must be properly defined and protected.Check text

Check text

Refer to the following report produced by the Data Set and Resource Data Collection: - SENSITVE.RPT(ZROS0020). Automated Analysis Refer to the following report produced by the Data Set and Resource Data Collection: - PDI(ZROS0020). EnsureVerify all ROSCOE resources and/or generic equivalent are properly protected according to the requirements specified in the CA ROSCOE Resources table in the z/OS STIG Addendum. Note: Wherever an access or user group is missing, use the Site Security Plan (SSP) to determine access and/or user group. If the following guidance is true, this is not a finding. The RACF resource access authorizations restrict access to the appropriate personnel. The RACF resource logging is correctly specified. The RACF resource access authorizations are defined with UACC(NONE) and NOWARNING.

V-224531CAT IIROSCOE Started Task name is not properly identified/defined to the system ACP.Title, Check text, Fix text, Discussion

Title

ROSCOE Started Task name is not properly identified / defined to the system ACP.

Check text

a) Refer to the following report produced by the RACF Data Collection: - RACFCMDS.RPT(LISTUSER). b) IfVerify that the Product started taskuserid(s) orfor Productthe batchROSCOE jobstarted useridtask(s) is defined(are) andproperly is assigned the RACF PROTECTED attribute, there is NO FINDINGdefined. c) If the abovefollowing isattributes untrueare defined, than this is not a FINDINGfinding. PROTECTED

Fix text

The ROSCOE system programmer and the IAOISSO will ensure that a product's Started Task(s) is properly Identified / defined to the System ACP. If the product requires a Started Task, verify that it is properly defined to the System ACP with the proper attributes. Most installation manuals will indicate how the Started Task is identified and any additional attributes that must be specified. A sample is provided here: au roscoe name('stc, roscoe') owner(stc) dfltgrp(stc) nopass

Discussion

Products that require a started task will require that the started task be restricted to certain resources, datasetsdata sets, and other system functions. ByDefining defining the started task as a userid to the system ACP, It allows the ACP to control the access and authorized users that require these capabilities. Failure to properly control these capabilities, could compromise of the operating system environment, ACP, and customer data.

V-224532CAT IIROSCOE Started task(s) must be properly defined to the STARTED resource class for RACF.Check text, Fix text, Discussion

Check text

Refer to the following report produced by the RACF Data Collection: - DSMON.RPT(RACSPT). Automated Analysis Refer to the following report produced by the RACF Data Collection: - PDI(ZROS0032). Verify that the ROSCOE started task(s) is (are) defined to the STARTED resource class profile and/or ICHRIN03 table entry, this is not a finding.

Fix text

The ROSCOE system programmer and the IAOISSO will ensure that a product's started task(s) is (are) properly identified and/or defined to the System ACP. A unique userid must be assigned for the ROSCOE started task(s) thru a corresponding STARTED class entry. The following sample set of commands is shown here as a guideline: rdef started ROSCOE.** uacc(none) owner(admin) audit(all(read)) stdata(user(ROSCOE) group(stc)) setr racl(started) ref

Discussion

Access to product resources should be restricted to only those individuals responsible for the application connectivity and who have a requirement to access these resources. Improper control of product resources could potentially compromise the operating system, ACP, and customer data.

V-224533CAT IIThe Roscoe Resource Class will be defined or active in the ACP.Check text, Fix text

Check text

Refer to the following report produced by the RACF Data Collection: - RACFCMDS.RPT(SETROPTS). - DSMON.RPT(RACCDT) - Alternate list of active resource classes. Automated Analysis Refer to the following report produced by the RACF Data Collection: - PDI(ZROS0038). EnsureIf that the ROSCOE resource class(es) is (are) definedactive, andthis activeis not a finding.

Fix text

The IASSO will ensure that the Product Resource Class(es) is (are) active. Issue the following commands: SETR CLASSACT(RO@RES) SETR GENERIC(RO@RES)

V-224534CAT IIProduct configuration/parameter values are not specified properly.Check text, Discussion

Check text

Have the products system programmer display the configuration/parameters control statements used in the current running product to define or enable security. This information is located in the SYSIN DD statement in the JCL of the STC/Batch job. Automated Analysis Refer to the following report produced by the z/OS Data Collection: - PDI(ZROS0040). VerifyIf the following specifications:keywords specify the values in the ROSCOE configuration/parameter control member, this is not a finding. Keyword Value EXTSEC RACF ACFEXT YES CLLEXT YES JOBEXT YES LIBEXT YES MONEXT YES PRVEXT YES RPFEXT YES UPSEXT YES If the above is true, this is not a finding. If the above is untrue, this is a finding.

Discussion

Product configuration/parameters control the security and operational characteristics of products. If these parameter values are improperly specified, security and operational controls may be weakened. This exposure may threaten the availability of the product applications, and compromise the confidentiality of customer data.

How these changes are found

Checks are matched across the two releases by V-number. A check counts as updated when DISA gave it a new rule revision (the r number in its SV-…_rule id) and its title, severity, check text, fix text, discussion, CCIs or other fields changed — the same comparison STIG Compare makes. Added checks are new V-numbers; removed checks are V-numbers V7R2 no longer has.

Comparing other releases, or this one against an older release? Pick any two in STIG Compare.